Create Transport Zones

Page last updated:

This topic provides instructions for creating transport zones for use with Enterprise PKS.

Prerequisites

Make sure you have completed all preceding NSX-T installation tasks.

About Transport Zones

In NSX-T Data Center, a transport zone (TZ) is a logical construct that controls which hosts a logical switch can reach. A transport zone defines a collection of hosts that can communicate with each other across a physical network infrastructure. This communication happens over one or more interfaces defined as Virtual Tunnel Endpoints (VTEPs).

There are two types of transport zones: Overlay and VLAN. An overlay transport zone is used by ESXi host transport nodes and NSX-T Edge Nodes. When an ESXi host or NSX-T Edge transport node is added to an Overlay transport zone, an N-VDS is installed on the ESXi host or NSX Edge Node. The VLAN transport zone is used by NSX-T Edge Nodes and ESXi host transport nodes for its VLAN uplinks. When an NSX-T Edge Node is added to a VLAN transport zone, a VLAN N-VDS is installed on the NSX-T Edge Node.

For more information, see Transport Zones in the NSX-T Data Center documentation.

Create Overlay Transport Zone

Create an Overlay Transport Zone (TZ-OVERLAY) for PKS control plane services and Kubernetes clusters overlay networks associated with associated with VDS hostswitch1.

  1. In NSX Manager, select System > Fabric > Transport Zones > Add.

  2. Enter a Name for the transport zone, such as TZ-OVERLAY.

  3. Enter a N-VDS Name, such as hostswitch1.

  4. Select a Host Membership Criteria (N-VDS mode): Standard or Enhanced Datapath.

    Note: In enhanced mode, only specific NIC configurations are supported (ESXi hosts v6.7+), and you must ensure that you configure the supported NICs. Refer to the NSX-T Data Center documentation for more information.

  5. For Traffic Type, select Overlay.

  6. (Optional) Enter one or more uplink teaming policy names.

  7. Click Add.

Create VLAN Transport Zone

Create the VLAN Transport Zone (TZ-VLAN) for NSX Edge Node uplinks (ingress/egress) for Kubernetes clusters associated with VDS hostswitch2.

  1. In NSX Manager, select System > Fabric > Transport Zones > Add.

  2. Enter a Name for the transport zone, such as TZ-VLAN.

  3. Enter N-VDS Name, such as hostswitch2.

  4. Select a Host Membership Criteria (N-VDS mode): Standard or Enhanced Datapath.

    Note: In enhanced mode, only specific NIC configurations are supported (ESXi hosts v6.7+), and you must ensure that you configure the supported NICs. Refer to the NSX-T Data Center documentation for more information.

  5. For Traffic Type, select VLAN.

  6. (Optional) Enter one or more uplink teaming policy names.

  7. Click Add.

Verify Transport Zone Creation

To verify transport zone creation:

  1. In NSX-T Manager select System > Fabric > Transport Zones.

  2. Verify that you see the TZ-OVERLAY and TZ-VLAN transport zones you created:

Next Step

Create Edge Node Uplink Profile.

NSX-T Installation Instructions Home

Installing and Configuring NSX-T for Enterprise PKS.


Please send any feedback you have to pks-feedback@pivotal.io.